2.4 Resulting Dimensions after Connecting User System Interface Cable
The resulting dimensions, after connecting the user system interface cable head to the user system,
are shown in figure 6.
12.0
Unit: mm
Tolerance: ±0.5 mm
User system
IC socket* mounted
on the user system
IC sockets* for
protection
Note: IC83-64075-GS4
manufactured by YAMAICHI ELECTRONICS Co., Ltd.
Cable head
Figure 6 Resulting Dimensions after Connecting User System Interface Cable