To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding. Renesas Electronics website: http://www.renesas.
Notice 1. 2. 3. 4. 5. 6. 7. All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office.
User’s Manual H8/3297 Series, H8/329 Series SDIP-64 User System Interface Cable (HS3297ECS61H) for E6000 Emulator User’s Manual
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Preface Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300 series. The HS3297ECS61H is a user system interface cable that connects an H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for an SDIP64 package (package code: DP-64S) for the H8/3297 series or H8/329 series MCU on the user system.
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................4 2.1 2.2 2.3 2.4 Connecting User System Interface Cable to Emulator Station ......................................... 4 Connecting User System Interface Cable to User System ................................................ 5 2.2.1 Installing IC Socket ...................................
Section 1 Configuration CAUTION Use an IC83-64075-GS4 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the DP-64S package IC socket on the user system. Figure 1 shows the configuration of the HS3297ECS61H user system interface cable for the DP-64S package.
To emulator station Cable body Cable head IC socket User system Figure 1 HS3297ECS61H User System Interface Cable 2
Table 1 lists the HS3297ECS61H components. Please make sure you have all of these components when unpacking. Table 1 HS3297ECS61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow the instructions below. 2.2.
Cable head Pin 1 User system IC socket (IC83-64075-GS4 manufactured by YAMAICHI ELECTRONICS Co., Ltd.
2.2.3 Connecting Cable Body to Cable Head Connect the cable body to the cable head.
2.3 Dimensions for User System Interface Cable Head 45.7 16.2 63.5 78.7 4.0 4- φ 2.5 21.6 10.6 57.7 68.6 The dimensions for the user system interface cable head are shown in figure 5. Unit: mm Tolerance: ±0.
2.4 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 6. 12.0 Cable head User system IC socket* mounted on the user system IC sockets* for protection Unit: mm Tolerance: ±0.5 mm Note: IC83-64075-GS4 manufactured by YAMAICHI ELECTRONICS Co., Ltd.
Section 3 Verifying Operation 1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3.
Section 4 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do not use this cable with any other emulator station. 3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable. 4.