To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding. Renesas Electronics website: http://www.renesas.
Notice 1. 2. 3. 4. 5. 6. 7. All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office.
User’s Manual H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Interface Cable for E6000 Emulator User’s Manual Renesas Microcomputer Development Environment System H8 Family / H8/300H Series HS3064BECH61H HS3064BECH61HE Rev.4.00 2008.
Notes regarding these materials 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of Renesas or any third party with respect to the information in this document. 2.
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products.
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use.
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3.
VI
Preface Thank you for purchasing this user system interface cable (HS3064BECH61H) for the Renesas’ original microcomputers H8/3048 group, H8/3052 group, H8/3062 group, H8/3067 group, and H8/3007 group.
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 2.2 2.3 2.4 2.5 Connecting User System Interface Cable to Emulator Station ......................................... 3 Connecting User System Interface Cable to User System ................................................ 5 2.2.1 Installing IC Socket................................
Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/ TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS3064BECH61H user system interface cable for the FP-100B/TFP-100B package. To emulator station CTS screws (M3 x 6 mm) for fastening the emulator station Cable body Screws (M2.6 x 6 mm) with flat washers Socket cover Screws (M2.
Table 1 lists the HS3064BECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3064BECH61H Components No. Component Quantity 1 Cable body 1 2 Cable head 1 3 IC socket 1 For the FP-100B/TFP-100B package 4 Socket cover 1 For installing an FP-100B/TFP-100B-packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket, and fasten the emulator station with two CTS screw (M3 x 6 mm) (figure 2).
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B/TFP-100B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3. 2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.294 N•m or less.
Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package on the user system with the four screws (M2.6 x 12 mm; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jigs.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100B/TFP-100B package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 17.10 (min.) 13.80 (max.) 0.5 x 24 = 12.00 ± 0.05 0.5 x 24 = 12.00 ± 0.05 0.30 ± 0.05 0.50 ± 0.05 0.50 ± 0.
2.4 Dimensions for User System Interface Cable Head 76.2 29.0 The dimensions for the user system interface cable head are shown in figure 6. 23.6 29.0 18.5 66.0 Unit: mm Tolerance: ±0.
2.5 Resulting Dimensions after Connecting User System Interface Cable 29.2 The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. 16.0 Cable head User system IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Unit: mm Tolerance: ±0.
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.294 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Screws (M2.6 x 6 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.
Section 4 Verifying Operation 1. Start up the emulator according to the procedures described in the H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group E6000 Emulator User's Manual (HS3064BEPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3.
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3064BEPI61H emulator. Do not use this cable with any other emulator station. 4.
6. The P1 jumper is used for testing. A jumper pin is inserted in pin 1 side. Do not remove the inserted jumper pin. CAUTION Insert the jumper pin in pin 3 side for P4 jumper when pin 10 of the MCU is not used as RESO. Otherwise the user system interface cable, the emulator product, and the user system will be damaged.
H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.3.00, March, 2003 Rev.4.00, August 20, 2008 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div. Renesas Solutions Corp. © 2008. Renesas Technology Corp., All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan RENESAS SALES OFFICES http://www.renesas.com Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Interface Cable for E6000 Emulator User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10J0616-0400