Site Schematic Check List
Access Control Design Guide
61
The door/elevator it is to control
Cable type and routing path to the controller
The port to be used for an RS485 reader (if applicable)
Two readers at one door: the location of the paired reader (if applicable), and the port number to use
at the door controller
Door Furniture
For each access-controlled door, mark the following:
Position of any required exit-request button
Whether a bypass circuit is needed
Details of any special noise-suppression circuitry
Details of any additional power supplies required for door releases
Cable type and routing path to controller
Cable supervision level for exit request and door monitor circuits
Additional Power Supplies (if necessary)
For any additional power supply, mark the following:
The purpose of the power supply
The output current and voltage specifications
The required location
The cable type and routing path
The main power source
The grounding point
The backup power source (normally a 12V 7AH battery)
SMS Software and PC Requirements
Specify the following:
The SMS software Edition to use (e.g. Professional)
The type and location of each SMS client
The sentinels to fit to the server(s)
Refer to the Software Installation Manual for PC requirements
Refer to the Digital Video Design Guide to plan digital video systems (if used)