User`s manual

Applilet EZ for HCD Controller CHAPTER 5 WINDOW REFERENCE
R20UT0435EJ1200 Rev. 12.00 38
Jul 31, 2014
(5) Power-On Level:
Specify the dimming level for when turning on power (as a value from 1 to 255).
(6) System F
ailure Level:
Specify the dimming level for when a failure occurs (as a value from 0 to 255).
(7) Max
. Level:
Specify the maximum dimming level (as a value from the minimum level to 254).
(8) M
in. Level:
Specify the minimum dimming level (as a value from the physical minimum level to the maximum level).
(9) Fade R
ate:
Specify the amount by which the dimming level is changed by fading (as a value from 1 to 15).
(10) Fade T
ime:
Specify the time required for the dimming level to be changed by fading (as a value from 0 to 15).
(11) Group
Specify the group the evaluation board belongs to. Multiple groups can be specified.
Function buttons
Button Description
Click this button to save the current settings and close the open dialog box.
Click this button to close the open dialog box without saving the current settings.