Applilet EZ for HCD Controller CHAPTER
4 APPLILET EZ FOR HCD CONTROLLER OPERATION
R20UT0435EJ1200 Rev. 12.00 26
Jul 31, 2014
Remark If an abnormality occurs during object code generation (*.hex) or flash writing, an error code may be
displayed.
Example: “code = xx”
Take the following countermeasures according to the code number (xx) displayed.
Code No. Countermeasures
2 Applilet EZ for HCD Controller may not be correctly installed. Reinstall it.
3 Data cannot be written because the folder that should be set via the [Folders...] setting on the [Setting]
menu does not exist.
Re-set an appropriate folder.
4 The compiler or assembler selected via the [Compiler] setting on the [Setting] menu cannot be found.
Check whether the compiler or assembler is correctly selected and installed. If it still cannot be found,
reinstall the compiler or assembler.
5 The compiler or assembler selected via the [Compiler] setting on the [Setting] menu is not correctly
installed.
Reinstall the compiler or assembler.
9 The folder set via the [Folders...] setting on the [Setting] menu or the BASEPROJECT folder in the
installation folder of Applilet EZ for HCD Controller is set as a read-only folder.
Cancel the read-only setting for the whole folder.
23 This is a system error of the compiler or assembler selected via the [Compiler] setting on the [Setting]
menu or the main body of Applilet EZ for HCD Controller.
Handle this error by checking the following points.
If a read-only folder or file exists under the folder set via the [Folders...] setting on the [Setting] menu,
cancel all read-only settings.
If the error still cannot be fixed, reinstall the compiler or assembler and the main body of Applilet EZ for
HCD Controller.
26 Illegal value of DALI propaty. Details of the error are displayed by text as below. If two or more errors
exist, only the first detected error is displayed.
"Power-On Level" < "Min. Level“, "Power-On Level" > "Max. Level”,
"System Failure Level" < "Min. Level“, "System Failure Level" > "Max. Level"
"Min. Level" < "Physical Min. Level“, "Min. Level" > "Max. Level“, "Min. Level" < 1
"Min. Level" > 254, "Max. Level" < "Min. Level“, "Max. Level" > 254,
"Max. Level" < 1, "Fade Rate" < 1, "Fade Rate" > 15, "Fade Time" < 1
"Fade Time" >15, "Random Address" < 0x000000, "Random Address" > 0xFFFFFF
<2> Writing preparation
If the board has a USB interface
Toggle the Program (PROG)/Run (RUN) switch on the evaluation board to “PROG” and then turn the evaluation
board off and on (The picture below shows an example of the EV-K0-HCD.). For details, refer to each user’s
manual of the evaluation boards.
If the board is using MINICUBE2
Connect the PC, MINICUBE2 and the board to each other, and turn ON the power of the evaluation board.
EV-K0-HCD
SW1
OFF
(PROG)
ON
(RUN)