User`s manual

M30850T2-EPB User’s Manual 5. Troubleshooting
R20UT0208EJ0300 Rev.3.00 Page 91 of 100
Sep 16, 2010
5. Troubleshooting
This chapter describes how to troubleshoot when this product does not work properly.
5.1 Flowchart to Remedy the Troubles
Figure 5.1 shows the flowchart to remedy the troubles from when power to the emulator is activated until the emulator
debugger starts up. Check this while the user system is disconnected. For the latest FAQs visit the Renesas Tools Homepage.
http://www.renesas.com/tools
Turning on emulator
Front panel LED
of emulator
1. Check connection of the power supply cable.
See
2.5 Connecting the Power Supply for the Emulator
(page 24).
2. Check that the power is properly supplied to the user system
See
2.6 Turning ON the Power
(page 25).
Init dialog box of emulator
debugger displayed
1. Check the operating environment etc. of the emulator debugger.
See the user's manual of the emulator debugger.
2. Reinstall the emulator debugger.
EMEM dialog box of
emulator debugger
See
5.2 (2) EMEM Dialog Box Does Not Appear at
Debugger Startup
(page 93).
Program window of emulator
debugger displayed
See
5.2 (3) Errors Occur at Debugger Startup
(page 94).
Emulator debugger startup completed
Normal
Normal
Normal
Normal
Not normal
Not normal/Error displayed
Not normal/Error displayed
Error displayed
Figure 5.1 Flowchart to remedy the troubles