Technical information
( 42 / 76 )
(2) Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 1)
Figure 3.15 shows how to connect the emulation pod probe to a 100-pin 0.65-mm-pitch QFP
(100P6S-A) foot pattern on the target system with the M3T-DUMMY100S (not included), and here
following is its procedure. For details on the M3T-DUMMY100S, refer to its user's manual.
(1) Attach the M3T-DUMMY100S to the target system.
(2) Attach the M3T-FLX-100LCC to the M3T-DUMMY100S.
Figure 3.15 Connecting a 100-pin 0.65-mm-pitch foot pattern (part 1)
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
• The small connectors of the M3T-DUMMY100S are guaranteed for only 20
insertion/removal iterations.
FLX100
(2)
(1)
100-pin 0.65-mm-pitch
(10P6S-A) foot pattern
No. 1 pin
Target system
M3T-DUMMY100S
(separately available)
Evaluation with actual MCU
MCU with
flash memory etc.