Technical information
( 41 / 76 )
(1) Connecting to a 100-pin 0.65-mm-pitch LCC Socket
When connecting the emulation pod probe to a 100-pin LCC socket (Yamaichi Electronics Co., Ltd.
IC61-1004-051 etc.) on the target system, following the procedure below.
(1) Attach the FLX100 to the M3T-FLX-100LCC.
(2) Attach the M3T-FLX-100LCC to the 100-pin LCC socket.
Figure 3.14 Connecting a 100-pin 0.65-mm-pitch LCC socket
CAUTION
Notes on Connecting Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
• The small connectors of the M3T-FLX-100LCC are guaranteed for only 20
insertion/removal iterations.
• The IC61-1004-051 included this product is guaranteed for only 20 insertion/
removal iterations.
• For purchasing the IC61-1004-051 and for any inquiry for it, contact Yamaichi
Electronics Co., Ltd.
FLX100
100-pin LCC socket
M3T-FLX-100LCC
No. 1 pin
Target system
(1)
(2)