Technical information
( 37 / 76 )
3.4 A-D Conversion Bypass Capacitor
The emulation pod has foot patterns on the board for mounting a bypass capacitor. Mount a suitable
bypass capacitor as occasion demands.
Figure 3.9 shows where the bypass capacitors are mounted, whereas Figure 3.10 shows an
enlargement of the foot patterns.
Figure 3.10 Foot patterns of an A-D conversion bypass capacitor
IMPORTANT
Note on the A-D Converter:
• Because a flexible board and other devices are used between the evaluation MCU
and the target system, the A-D converter operates differently from the actual MCU.
Make the final evaluation of the A-D converter from the actual MCU.
Figure 3.9 Position for mounting A-D conversion bypass capacitor (underside of the M30620T2-PRT)