Technical information
4.2.2. CRYSTAL CHOICE 
The operating crystal frequency has been chosen to support the fastest operation with the fastest serial operating speeds. 
The value of the crystal is 18.432MHz. 
The following table shows the baud rates and Baud Rate Register (BRR) setting required for each communication rate using 
the above default operating speed. It also confirms the resultant baud rate and the bit error rate that can be expected. 
Baud Rate Register Settings for Serial Communication Rates 
SMR 
Setting: 
0 1 2 3 
Comm. 
Baud 
BRR 
setting 
Actual 
Rate 
ERR 
(%) 
BRR 
setting 
Actual 
Rate 
ERR 
(%) 
BRR 
setting 
Actual 
Rate 
ERR 
(%) 
BRR 
setting 
Actual 
Rate 
ERR 
(%) 
110 
Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid 81  110  -0.22 
300 
Invalid Invalid Invalid Invalid Invalid Invalid 119  300  0.00  29  300  0.00 
1200 
Invalid Invalid Invalid 119  1200 0.00  29  1200 0.00  7  1125 -6.25 
2400 
239  2400 0.00  59  2400 0.00  14  2400 0.00  3  2250 -6.25 
4800 
119  4800 0.00  29  4800 0.00  7  4500 -6.25 1  4500 -6.25 
9600 
59  9600 0.00  14  9600 0.00  3  9000 -6.25 Invalid Invalid Invalid 
19200 
29 19200 0.00 7 18000 -6.25 1 18000 -6.25 Invalid Invalid Invalid 
38400 
14  38400  0.00  3  36000  -6.25  Invalid Invalid Invalid Invalid Invalid Invalid 
57600 
9  57600  0.00  2  48000  -16.67  Invalid Invalid Invalid Invalid Invalid Invalid 
115200 
4  115200 0.00  0  144000 25.00  Invalid Invalid Invalid Invalid Invalid Invalid 
230400* 
2  192000 -16.67  Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid 
460800* 
0  576000 25.00  Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid 
TABLE 4-2 CRYSTAL FREQUENCIES FOR RS232 COMMUNICATION 
* Note: The device used to convert the RS232 serial information to logic signals for the microcontroller is limited to 
120kBaud. The rates above this level can only be utilised if the user provides direct logic level communications. 
The user may replace the HC49/U surface mounted AT cut crystal with another of similar type within the operating frequency 
of the microcontroller device. Please refer to the hardware manual for the microcontroller for the valid operating range. 
Alternatively the user may fit an oscillator module – or provide an external clock source. When providing an oscillator module 
or external source it is highly recommended that the load capacitors for the AT crystal are removed from the PCB. These are 
physically placed within the PCB outline of the oscillator module for easy location and to ensure they are removed when 
using this option. 
When changing the crystal frequency the pre-loaded debugging monitor will not function. In this situation the user is 
responsible for providing code to evaluate the device away from the default operating speed. 
4.2.3. REMOVABLE COMPONENT INFORMATION. 
This information is provided to allow the replacement of components removed from the board as described in section 4.2.2. 
Component Cct. Ref Value Rating  Manufacturer 
Load Resistor (X2)  R8 
1MΩ 
0805 1%  Welwyn WCR Series 
Load Resistor (X3)  R7 
1MΩ 
0805 1%  Welwyn WCR Series 
Load capacitors (X2)  C2,C3  12pF  0603 10% 25V  AVX 0603 3 A 150 KAT 
Load capacitors (X3)  C4,C5  15pF  0603 10% 25V  AVX 0603 3 A 150 KAT 
TABLE 4-3: REMOVABLE COMPONENT INFORMATION 
Care must be taken not to damage the tracking around these components. Only use soldering equipment designed for 
surface mount assembly and rework. 
4.3. SPI EEPROM 
The board has been tested with an Atmel AT25040N-10SA-2.7 SPI EEPROM device (Not supplied). 
The device should be connected to P30, P31, P32 and P67 using 0R links on R15, R16, R17 and R21. Alternative 
connections are available, refer to section 5.3 for more information. 
Do not fit the CAN transceiver if the SPI device is fitted while using the settings above. 
 7 