Datasheet
Section 2 CPU 
Rev. 3.00 Mar. 15, 2006 Page 26 of 526 
REJ09B0060-0300   
Table 2.8  System Control Instructions 
Instruction Size* Function 
TRAPA — Starts trap-instruction exception handling. 
RTE  —  Returns from an exception-handling routine. 
SLEEP — Causes a transition to a power-down state. 
LDC B/W (EAs) → CCR 
Moves the source operand contents to the CCR. The CCR size is one byte, 
but in transfer from memory, data is read by word access. 
STC B/W CCR → (EAd) 
Transfers the CCR contents to a destination location. The condition code 
register size is one byte, but in transfer to memory, data is written by word 
access. 
ANDC B CCR ∧ #IMM → CCR 
Logically ANDs the CCR with immediate data. 
ORC B CCR ∨ #IMM → CCR 
Logically ORs the CCR with immediate data. 
XORC B CCR ⊕ #IMM → CCR 
Logically XORs the CCR with immediate data. 
NOP  —  PC + 2 → PC 
Only increments the program counter. 
Note:  *  Refers to the operand size. 
 B: Byte 
 W: Word 
Table 2.9  Block Data Transfer Instructions 
Instruction Size Function 
EEPMOV.B —  if R4L ≠ 0 then 
 Repeat @ER5+ → @ER6+, 
 R4L–1 → R4L 
 Until R4L = 0 
else next; 
EEPMOV.W —  if R4 ≠ 0 then 
 Repeat @ER5+ → @ER6+, 
 R4–1 → R4 
 Until R4 = 0 
else next; 
Transfers a data block. Starting from the address set in ER5, transfers data 
for the number of bytes set in R4L or R4 to the address location set in ER6. 
Execution of the next instruction begins as soon as the transfer is 
completed. 