Datasheet
Section 23 Electrical Characteristics 
Rev. 3.00 Mar. 15, 2006 Page 454 of 526 
REJ09B0060-0300   
Table 23.13  I
2
C Bus Interface Timing 
V
CC
 = 2.7 V to 5.5 V, V
SS
 = 0.0 V, T
a
 = –20 to +75°C, unless otherwise indicated. 
Test 
 Values  
Reference
Item Symbol Condition Min. Typ. Max. Unit Figure 
SCL input cycle time  t
SCL
  12t
cyc
 + 600    ns Figure 23.4 
SCL input high width  t
SCLH
  3t
cyc
 + 300     ns  
SCL input low width  t
SCLL
  5t
cyc
 + 300     ns  
SCL and SDA input 
fall time 
t
Sf
     300 ns  
SCL and SDA input 
spike pulse removal 
time 
t
SP
     1t
cyc
 ns  
SDA input bus-free 
time 
t
BUF
  5t
cyc
     ns  
Start condition input 
hold time 
t
STAH
  3t
cyc
     ns  
Retransmission start 
condition input setup 
time 
t
STAS
  3t
cyc
     ns  
Setup time for stop 
condition input 
t
STOS
  3t
cyc
     ns  
Data-input setup time  t
SDAS
  1t
cyc
+20     ns  
Data-input hold time  t
SDAH
  0     ns  
Capacitive load of 
SCL and SDA 
c
b
  0   400 pF  
SCL and SDA output 
fall time 
t
Sf
 V
CC
 = 4.0 
to 5.5 V 
   250 ns  
     300    