Section 20 Power-On Reset and Low-Voltage Detection Circuits (Optional) 
    Rev. 3.00 Mar. 15, 2006 Page 397 of 526 
   REJ09B0060-0300 
20.3.2 Low-Voltage Detection Circuit 
Use this circuit in the system in which the power supply voltage Vcc is between 4.5 and 5.5 V. If 
so, the contents described in the section of electrical characteristics are guaranteed. 
LVDR (Reset by Low Voltage Detect) Circuit: 
Figure 20.3 shows the timing of the LVDR function. The LVDR enters the module-standby state 
after a power-on reset is canceled. To operate the LVDR, set the LVDE bit in LVDCR to 1, wait 
for 50 µs (t
LVDON
) until the reference voltage and the low-voltage-detection power supply have 
stabilized by a software timer, etc., then set the LVDRE bit in LVDCR to 1. After that, the output 
settings of ports must be made. To cancel the low-voltage detection circuit, first the LVDRE bit 
should be cleared to 0 and then the LVDE bit should be cleared to 0. The LVDE and LVDRE bits 
must not be cleared to 0 simultaneously because incorrect operation may occur. 
When the power-supply voltage falls below the Vreset voltage (typ. = 2.3 V or 3.6 V), the LVDR 
clears the LVDRES signal to 0, and resets the prescaler S. The low-voltage detection reset state 
remains in place until a power-on reset is generated. When the power-supply voltage rises above 
the Vreset voltage again, the prescaler S starts counting. It counts 131,072 clock (φ) cycles, and 
then releases the internal reset signal. In this case, the LVDE, LVDSEL, and LVDRE bits in 
LVDCR are not initialized. 
Note that if the power supply voltage (Vcc) falls below V
LVDRmin
 = 1.0 V and then rises from that 
point, the low-voltage detection reset may not occur. 
If the power supply voltage (Vcc) falls below Vpor = 100 mV, a power-on reset occurs. 