Datasheet
Section 19 A/D Converter 
    Rev. 3.00 Mar. 15, 2006 Page 381 of 526 
   REJ09B0060-0300 
19.3.2  A/D Control/Status Register (ADCSR) 
ADCSR consists of the control bits and conversion end status bits of the A/D converter. 
Bit Bit Name 
Initial 
Value R/W Description 
7  ADF  0  R/W  A/D End Flag 
[Setting conditions] 
•  When A/D conversion ends in single mode 
•  When A/D conversion ends once on all the channels 
selected in scan mode 
[Clearing condition] 
When 0 is written after reading ADF = 1 
6  ADIE  0  R/W  A/D Interrupt Enable 
A/D conversion end interrupt request (ADI) is enabled 
by ADF when this bit is set to 1 
5 ADST 0  R/W A/D Start 
Setting this bit to 1 starts A/D conversion. In single 
mode, this bit is cleared to 0 automatically when 
conversion on the specified channel is complete. In 
scan mode, conversion continues sequentially on the 
specified channels until this bit is cleared to 0 by 
software, a reset, or a transition to standby mode. 
4 SCAN 0  R/W Scan Mode 
Selects single mode or scan mode as the A/D 
conversion operating mode. 
0: Single mode 
1: Scan mode 
3 CKS 0  R/W Clock Select 
Selects the A/D conversions time. 
0: Conversion time = 134 states (max.) 
1: Conversion time = 70 states (max.) 
Clear the ADST bit to 0 before switching the conversion 