Datasheet
Section 17 Serial Communication Interface 3 (SCI3) 
    Rev. 3.00 Mar. 15, 2006 Page 337 of 526 
   REJ09B0060-0300 
1 frame
Start
bit
Start
bit
Receive 
data (ID1)
Receive data 
(Data1)
MPB MPB
Stop
bit
Stop
bit
Mark state 
(idle state)
1 frame
01D0D1D711 110D0D1 D7
ID1
0
Serial
data
MPIE
RDRF
RDR
value
RDR
value
LSI
operation
RXI interrupt
request
MPIE cleared 
to 0
User 
processing
RDRF flag
cleared 
to 0
RXI interrupt request
is not generated, and
RDR retains its state
RDR data read
When data is not 
this station's ID, 
MPIE is set to 1 
again
1 frame
Start
bit
Start
bit
Receive 
data (ID2)
Receive data 
(Data2)
MPB MPB
Stop
bit
Stop
bit
Mark state 
(idle state)
1 frame
01D0D1D711 110
(a) When data does not match this receiver's ID
(b) When data matches this receiver's ID
D0 D1 D7
ID2 Data2ID1
0
Serial
data
MPIE
RDRF
LSI
operation
RXI interrupt
request
MPIE cleared 
to 0
User 
processing
RDRF flag
cleared 
to 0
RXI interrupt
request
RDRF flag
cleared 
to 0
RDR data read When data is 
this station's 
ID, reception 
is continued
RDR data read 
MPIE set to 1 
again
Figure 17.18 Example of SCI3 Reception Using Multiprocessor Format 
(Example with 8-Bit Data, Multiprocessor Bit, One Stop Bit) 