Datasheet
Section 14 Timer Z 
    Rev. 3.00 Mar. 15, 2006 Page 285 of 526 
   REJ09B0060-0300 
6.  Contention between Count Clearing and Increment Operations by Input Capture: If an input 
capture and increment signals are simultaneously generated, count clearing by the input 
capture operation has priority without an increment operation. The TCNT contents before 
clearing counter are transferred to GR. Figure 14.57 shows the timing in this case. 
TCNT
Input capture 
signal 
Counter clear 
signal
TCNT input clock
Clearing has priority. 
N
H'0000
GR
N
φ
Figure 14.57 Contention between Count Clearing and Increment Operations 
by Input Capture 