Rev. 3.00 Mar. 15, 2006 Page 244 of 526 
REJ09B0060-0300   
14.4.3 Input Capture Function 
The TCNT value can be transferred to GR on detection of the input edge of the input 
capture/output compare pin (FTIOA, FTIOB, FTIOC, or FTIOD). Rising edge, falling edge, or 
both edges can be selected as the detected edge. When the input capture function is used, the pulse 
width or period can be measured. 
Figure 14.16 shows an example of the input capture operation setting procedure. 
[1]  Designate GR as an input capture register by 
means of TIOR, and select rising edge, falling 
edge, or both edges as the input edge of the 
input capture signal.
[2]  Set the STR bit in TSTR to 1 to start the TCNT 
counter operation.
[1]
Input selection
Select input edge of 
input capture
[2]
Start counter operation
<Input capture operation>
Figure 14.16 Example of Input Capture Operation Setting Procedure 