Datasheet
Section 14 Timer Z 
    Rev. 3.00 Mar. 15, 2006 Page 243 of 526 
   REJ09B0060-0300 
GRB
GRA
H'0000
FTIOB
Toggle output 
Toggle output 
Time
TCNT value
FTIOA
Figure 14.14 Example of Toggle Output Operation 
2.  Output compare timing 
The compare match signal is generated in the last state in which TCNT and GR match (when 
TCNT changes from the matching value to the next value). When the compare match signal is 
generated, the output value selected in TIOR is output at the compare match output pin 
(FTIOA, FTIOB, FTIOC, or FTIOD). When TCNT matches GR, the compare match signal is 
generated only after the next TCNT input clock pulse is input. 
Figure 14.15 shows an example of the output compare timing. 
TCNT
FTIOA to FTIOD 
Compare match
signal
TCNT input
GR
N
N
N+1
φ
Figure 14.15 Output Compare Timing 