Datasheet
Section 14 Timer Z 
    Rev. 3.00 Mar. 15, 2006 Page 229 of 526 
   REJ09B0060-0300 
14.3.9  Timer Control Register (TCR) 
The TCR registers select a TCNT counter clock, an edge when an external clock is selected, and 
counter clearing sources. Timer Z has a total of two TCR registers, one for each channel. 
Bit Bit Name 
Initial 
Value R/W Description 
7 
6 
5 
CCLR2 
CCLR1 
CCLR0 
0 
0 
0 
R/W 
R/W 
R/W 
Counter Clear 2 to 0 
000: Disables TCNT clearing 
001: Clears TCNT by GRA compare match/input 
capture*
1
010: Clears TCNT by GRB compare match/input 
capture*
1
011: Synchronization clear; Clears TCNT in synchronous 
with counter clearing of the other channel's timer*
2
100: Disables TCNT clearing 
101: Clears TCNT by GRC compare match/input 
capture*
1
110: Clears TCNT by GRD compare match/input 
capture*
1
111: Synchronization clear; Clears TCNT in synchronous 
with counter clearing of the other channel's timer*
2
4 
3 
CKEG1 
CKEG0 
0 
0 
R/W 
R/W 
Clock Edge 1 and 0  
00: Count at rising edge 
01: Count at falling edge 
1X: Count at both edges 
2 
1 
0 
TPSC2 
TPSC1 
TPSC0 
0 
0 
0 
R/W 
R/W 
R/W 
Time Prescaler 2 to 0 
000: Internal clock: count by φ 
001: Internal clock: count by φ/2 
010: Internal clock: count by φ/4 
011: Internal clock: count by φ/8 
1XX: External clock: count by FTIOA0 (TCLK) pin input 
Notes:  1.  When GR functions as an output compare register, TCNT is cleared by compare match. 
When GR functions as input capture, TCNT is cleared by input capture. 
  2.  Synchronous operation is set by TMDR. 
  3.  X: Don't care 