Datasheet
Section 14 Timer Z 
Rev. 3.00 Mar. 15, 2006 Page 214 of 526 
REJ09B0060-0300   
•  Eleven interrupt sources 
  Four compare match/input capture interrupts and an overflow interrupt are available for 
each channel. An underflow interrupt can be set for channel 1. 
Table 14.1  Timer Z Functions 
Item  Channel 0  Channel 1 
Count clock  Internal clocks: φ, φ/2, φ/4, φ/8 
External clock: FTIOA0 (TCLK) 
General registers 
(output compare/input 
capture registers) 
GRA_0, GRB_0, GRC_0, GRD_0  GRA_1, GRB_1, GRC_1, GRD_1 
Buffer register  GRC_0, GRD_0  GRC_1, GRD_1 
I/O pins  FTIOA0, FTIOB0, FTIOC0, 
FTIOD0 
FTIOA1, FTIOB1, FTIOC1, 
FTIOD1 
Counter clearing function  Compare match/input capture of 
GRA_0, GRB_0, GRC_0, or 
GRD_0 
Compare match/input capture of 
GRA_1, GRB_1, GRC_1, or 
GRD_1 
0 output  Yes  Yes 
1 output  Yes  Yes 
Compare 
match output
output Yes  Yes 
Input capture function  Yes  Yes 
Synchronous operation  Yes  Yes 
PWM mode  Yes  Yes 
Reset synchronous PWM 
mode 
Yes
Yes
Complementary PWM 
mode 
Yes
Yes
Buffer function 
Yes
Yes
Interrupt sources  Compare match/input capture A0 
to D0 
Overflow 
Compare match/input capture A1 
to D1 
Overflow 
Underflow 