Datasheet
Section 6 Power-Down Modes 
Rev. 3.00 Mar. 15, 2006 Page 76 of 526 
REJ09B0060-0300   
6.1.1  System Control Register 1 (SYSCR1) 
SYSCR1 controls the power-down modes, as well as SYSCR2. 
Bit Bit Name 
Initial 
Value R/W Description 
7 SSBY 0  R/W Software Standby 
This bit selects the mode to transit after the execution 
of the SLEEP instruction. 
0: Enters sleep mode or subsleep mode. 
1: Enters standby mode. 
For details, see table 6.2. 
6 
5 
4 
STS2 
STS1 
STS0 
0 
0 
0 
R/W 
R/W 
R/W 
Standby Timer Select 2 to 0 
These bits designate the time the CPU and peripheral 
modules wait for stable clock operation after exiting 
from standby mode, subactive mode, or subsleep 
mode to active mode or sleep mode due to an interrupt. 
The designation should be made according to the clock 
frequency so that the waiting time is at least 6.5 ms. 
The relationship between the specified value and the 
number of wait states is shown in table 6.1. When an 
external clock is to be used, the minimum value (STS2 
= STS1 = STS0 =1) is recommended. 
3 NESEL 0  R/W Noise Elimination Sampling Frequency Select 
The subclock pulse generator generates the watch 
clock signal (φ
W
) and the system clock pulse generator 
generates the oscillator clock (φ
OSC
). This bit selects the 
sampling frequency of the oscillator clock when the 
watch clock signal (φ
W
) is sampled. When φ
OSC
 = 4 to 20 
MHz, clear NESEL to 0. 
0: Sampling rate is φ
OSC
/16 
1: Sampling rate is φ
OSC
/4 
2 
1 
0 
 
 
 
0 
0 
0 
 
 
 
Reserved 
These bits are always read as 0. 