Type Instruction Size*
1
Function
System control
instructions
ANDC B CCR #IMM CCR, EXR #IMM EXR
Logically ANDs the CCR or EXR contents with
immediate data.
ORC B CCR #IMM CCR, EXR #IMM EXR
Logically ORs the CCR or EXR contents with immediate
data.
XORC B CCR #IMM CCR, EXR #IMM EXR
Logically exclusive-ORs the CCR or EXR contents with
immediate data.
NOP PC + 2 PC
Only increments the program counter.
Block data
transfer
instruction
EEPMOV.B
EEPMOV.W
if R4L 0 then
Repeat @ER5+ @ER6+
R4L–1 R4L
Until R4L = 0
else next;
if R4 0 then
Repeat @ER5+ @ER6+
R4–1 R4
Until R4 = 0
else next;
Transfers a data block according to parameters set in
general registers R4L or R4, ER5, and ER6.
R4L or R4: size of block (bytes)
ER5: starting source address
ER6: starting destination address
Execution of the next instruction begins as soon as the
transfer is completed.
Notes: 1. Size refers to the operand size.
B: Byte
W: Word
L: Longword
2. Only register ER0, ER1, ER4, or ER5 should be used when using the TAS instruction.