Rev.6.00 Oct.28.2004 page 668 of 1016
REJ09B0138-0600H
21.1.1 Register Configuration
Power-down modes are controlled by the SBYCR, SCKCR, and MSTPCR registers. Table 21-2 summarizes these
registers.
Table 21-2 Power-Down Mode Registers
Name Abbreviation R/W Initial Value Address*
Standby control register SBYCR R/W H'08 H'FF38
System clock control register SCKCR R/W H'00 H'FF3A
Module stop control register H MSTPCRH R/W H'3F H'FF3C
Module stop control register L MSTPCRL R/W H'FF H'FF3D
Note: * Lower 16 bits of the address.