Datasheet

Rev.6.00 Oct.28.2004 page 612 of 1016
REJ09B0138-0600H
The status polling I/O
6
and I/O
7
pin information is retained until the next command write. Until the next command
write is performed, reading is possible by enabling CE and OE.
19.13.7 Status Read Mode
Status read mode is used to identify what type of abnormal end has occurred. Use this mode when an abnormal end
occurs in auto-program mode or auto-erase mode.
The return code is retained until a command write for other than status read mode is performed.
Table 19-26 AC Characteristics in Status Read Mode
Conditions: V
CC
= 5.0 V ±10%, V
SS
= 0 V, T
a
= 25°C ±5°C
Item Symbol Min Max Unit
Command write cycle t
nxtc
20 µs
CE hold time t
ceh
0—ns
CE setup time t
ces
0—ns
Data hold time t
dh
50 ns
Data setup time t
ds
50 ns
Write pulse width t
wep
70 ns
OE output delay time t
oe
150 ns
Disable delay time t
df
100 ns
CE output delay time t
ce
150 ns
WE rise time t
r
—30ns
WE fall time t
f
—30ns
CE
Address
Data
OE
WE
t
ces
t
nxtc
t
nxtc
t
df
Note: I/O
2
and I/O
3
are undefined.
t
ces
t
dh
t
wep
t
wep
Data
t
dh
t
oe
t
ce
t
nxtc
H'71
t
f
t
r
t
f
t
r
t
ceh
t
ds
t
ds
H'71
t
ceh
Figure 19-31 Status Read Mode Timing Waveforms