Table 19-20 Programmer Mode Commands
Number
1st Cycle 2nd Cycle
Command Name of Cycles Mode Address Data Mode Address Data
Memory read mode 1 + n Write × H'00 Read RA Dout
Auto-program mode 129 Write × H'40 Write PA Din
Auto-erase mode 2 Write × H'20 Write × H'20
Status read mode 2 Write × H'71 Write × H'71
Legend:
RA: Read address
PA: Program address
×: Don’t care
Notes: 1. In auto-program mode. 129 cycles are required for command writing by a simultaneous 128-byte write.
2. In memory read mode, the number of cycles depends on the number of address write cycles (n).
19.13.4 Memory Read Mode
After the end of an auto-program, auto-erase, or status read operation, the command wait state is entered. To read
memory contents, a transition must be made to memory read mode by means of a command write before the read is
executed.
Command writes can be performed in memory read mode, just as in the command wait state.
Once memory read mode has been entered, consecutive reads can be performed.
After power-on, memory read mode is entered.
Table 19-21 AC Characteristics in Memory Read Mode
Conditions: V
CC
= 5.0 V ±10%, V
SS
= 0 V, T
a
= 25°C ±5°C
Item Symbol Min Max Unit
Command write cycle t
nxtc
20 µs
CE hold time t
ceh
0—ns
CE setup time t
ces
0—ns
Data hold time t
dh
50 ns
Data setup time t
ds
50 ns
Write pulse width t
wep
70 ns
WE rise time t
r
—30ns
WE fall time t
f
—30ns