Bit 7—A/D End Flag (ADF): Status flag that indicates the end of A/D conversion.
Bit 7
ADF Description
0 [Clearing conditions] (Initial value)
• When 0 is written to the ADF flag after reading ADF = 1
• When the DTC is activated by an ADI interrupt and ADDR is read
1 [Setting conditions]
• Single mode: When A/D conversion ends
• Scan mode: When A/D conversion ends on all specified channels
Bit 6—A/D Interrupt Enable (ADIE): Selects enabling or disabling of interrupt (ADI) requests at the end of A/D
conversion.
Bit 6
ADIE Description
0 A/D conversion end interrupt (ADI) request disabled (Initial value)
1 A/D conversion end interrupt (ADI) request enabled
Bit 5—A/D Start (ADST): Selects starting or stopping on A/D conversion. Holds a value of 1 during A/D conversion.
The ADST bit can be set to 1 by software, a timer conversion start trigger, or the A/D external trigger input pin (ADTRG).
Bit 5
ADST Description
0
• A/D conversion stopped (Initial value)
1
• Single mode: A/D conversion is started. Cleared to 0 automatically when
conversion on the specified channel ends.
• Scan mode: A/D conversion is started. Conversion continues sequentially on the
selected channels until ADST is cleared to 0 by software, a reset, or
a transition to standby mode or module stop mode.
Bit 4—Scan Mode (SCAN): Selects single mode or scan mode as the A/D conversion operating mode. See section 16.4,
Operation, for single mode and scan mode operation. Only set the SCAN bit while conversion is stopped (ADST = 0).
Bit 4
SCAN Description
0 Single mode (Initial value)
1 Scan mode
Bit 3—Clock Select (CKS): Sets the A/D conversion time. Only change the conversion time while conversion is stopped
(ADST = 0).
Bit 3
CKS Description
0 Conversion time = 266 states (max.) (Initial value)
1 Conversion time = 134 states (max.)