Datasheet

Rev.6.00 Oct.28.2004 page 424 of 1016
REJ09B0138-0600H
11.3.2 Output Timing
If pulse output is enabled, NDR contents are transferred to PODR and output when the specified compare match event
occurs. Figure 11-3 shows the timing of these operations for the case of normal output in groups 2 and 3, triggered by
compare match A.
TCNT
N N+1
ΓΈ
TGRA
N
Compare match
A signal
NDRH
mn
PODRH
PO8 to PO15
n
mn
Figure 11-3 Timing of Transfer and Output of NDR Contents (Example)