Table 16.3 A/D Conversion Time (Single Mode)
CKS1 = 0 CKS1 = 1
CKS0 = 0 CKS0 = 1 CKS0 = 0 CKS0 = 1
Item Symbol Min Typ Max Min Typ Max Min Typ Max Min Typ Max
A/D conversion
start delay time
t
D
18 — 33 10 — 16 6 — 9 4 — 5
Input sampling
time
t
SPL
— 127 — — 63 — — 31 — — 15 —
A/D conversion
time
t
CONV
515 — 530 259 — 266 131 — 134 67 — 68
Note: Values in the table are the number of states.
Table 16.4 A/D Conversion Time (Scan Mode)
CKS1 CKS0 Conversion Time (State)
0 512 (Fixed) 0
1 256 (Fixed)
1 0 128 (Fixed)
1 64 (Fixed)