Table 14.13 SCI Interrupt Sources
Channel
Name
Interrupt Source
Interrupt Flag
DTC
Activation
DMAC
Activation
Priority
ERI0 Receive Error ORER, FER, PER Not possible Not possible High
RXI0 Receive Data Full RDRF Possible Possible
TXI0 Transmit Data Empty TDRE Possible Possible
0
TEI0 Transmission End TEND Not possible Not possible
ERI1 Receive Error ORER, FER, PER Not possible Not possible
RXI1 Receive Data Full RDRF Possible Possible
TXI1 Transmit Data Empty TDRE Possible Possible
1
TEI1 Transmission End TEND Not possible Not possible
ERI2 Receive Error ORER, FER, PER Not possible Not possible
RXI2 Receive Data Full RDRF Possible Not possible
TXI2 Transmit Data Empty TDRE Possible Not possible
2
TEI2 Transmission End TEND Not possible Not possible
ERI3 Receive Error ORER, FER, PER Not possible Not possible
RXI3 Receive Data Full RDRF Possible Not possible
TXI3 Transmit Data Empty TDRE Possible Not possible
3
TEI3 Transmission End TEND Not possible Not possible
ERI4 Receive Error ORER, FER, PER Not possible Not possible 4
RXI4 Receive Data Full RDRF Possible Not possible
TXI4 Transmit Data Empty TDRE Possible Not possible
TEI4 Transmission End TEND Not possible Not possible Low