Datasheet

Section 14 Serial Communication Interface (SCI, IrDA)
Rev.6.00 Mar. 18, 2009 Page 591 of 980
REJ09B0050-0600
14.5.2 Multiprocessor Serial Data Reception
Figure 14.13 shows a sample flowchart for multiprocessor serial data reception. If the MPIE bit in
SCR is set to 1, data is skipped until data with a 1 multiprocessor bit is received. On receiving
data with a 1 multiprocessor bit, the receive data is transferred to RDR. An RXI interrupt request
is generated at this time. All other SCI operations are the same as in asynchronous mode. Figure
14.12 shows an example of SCI operation for multiprocessor format reception.