Datasheet

Section 14 Serial Communication Interface (SCI, IrDA)
Rev.6.00 Mar. 18, 2009 Page 585 of 980
REJ09B0050-0600
Table 14.11 shows the states of the SSR status flags and receive data handling when a receive
error is detected. If a receive error is detected, the RDRF flag retains its state before receiving
data. Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the
ORER, FER, PER, and RDRF bits to 0 before resuming reception. Figure 14.9 shows a sample
flowchart for serial data reception.
Table 14.11 SSR Status Flags and Receive Data Handling
SSR Status Flag
RDRF
*
ORER FER PER Receive Data Receive Error Type
1 1 0 0 Lost Overrun error
0 0 1 0 Transferred to RDR Framing error
0 0 0 1 Transferred to RDR Parity error
1 1 1 0 Lost Overrun error + framing error
1 1 0 1 Lost Overrun error + parity error
0 0 1 1 Transferred to RDR Framing error + parity error
1 1 1 1 Lost Overrun error + framing error +
parity error
Note: * The RDRF flag retains its state before data reception.