Datasheet
Section 15 D/A Converter 
Rev.7.00 Feb. 14, 2007  page 558 of 1108 
REJ09B0089-0700 
15.2.3  Module Stop Control Register (MSTPCR) 
 MSTPCRH  MSTPCRL 
Bit  : 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 
Initial value : 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 
R/W  :  R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 
MSTPCR is a 16-bit readable/writable register that performs module stop mode control. 
When the MSTP10 bit in MSTPCR is set to 1, D/A converter operation stops at the end of the bus 
cycle and a transition is made to module stop mode. Registers cannot be read or written to in 
module stop mode. For details, see section 19.5, Module Stop Mode. 
MSTPCR is initialized to H'3FFF by a reset and in hardware standby mode. It is not initialized in 
software standby mode. 
Bit 10—Module Stop (MSTP10): Specifies the D/A converter (channels 0, 1) module stop mode. 
Bit 10 
MSTP10 
Description 
0  D/A converter (channels 0, 1) module stop mode cleared 
1  D/A converter (channels 0, 1) module stop mode set    (Initial value)