Datasheet
Section 6 Bus Controller 
Rev.7.00 Feb. 14, 2007  page 159 of 1108 
REJ09B0089-0700 
6.4.3 Valid Strobes 
Table 6.4 shows the data buses used and valid strobes for the access spaces. 
In a read, the RD signal is valid without discrimination between the upper and lower halves of the 
data bus. 
In a write, the HWR signal is valid for the upper half of the data bus, and the LWR signal for the 
lower half. 
Table 6.4  Data Buses Used and Valid Strobes 
Area 
Access 
Size 
Read/ 
Write 
Address 
Valid 
Strobe 
Upper Data Bus 
(D
15
 to D
8
) 
Lower Data Bus 
(D
7
 to D
0
) 
Byte Read —  RD Valid  Invalid 
8-bit access 
space 
 Write — HWR  Hi-Z 
Byte Read Even  RD Valid  Invalid 16-bit access 
space 
 Odd   Invalid  Valid 
 Write Even HWR Valid  Hi-Z 
  Odd LWR Hi-Z  Valid 
 Word Read — RD Valid  Valid 
 Write — HWR, LWR Valid  Valid 
Notes: Hi-Z: High impedance 
  Invalid: Input state; input value is ignored. 