Section 9 16-Bit Timer Pulse Unit (TPU)
Rev.7.00 Feb. 14, 2007 page 339 of 1108
REJ09B0089-0700
Bit n
SYNCn
Description
0 TCNTn operates independently (TCNT presetting/clearing is unrelated to
other channels) (Initial value)
1 TCNTn performs synchronous operation
TCNT synchronous presetting/synchronous clearing is possible
n = 5 to 0
9.2.10 Module Stop Control Register (MSTPCR)
MSTPCRH MSTPCRL
Bit : 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Initial value : 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
R/W : R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
MSTPCR is a 16-bit readable/writable register that performs module stop mode control.
When the MSTP13 bit in MSTPCR is set to 1, TPU operation stops at the end of the bus cycle and
a transition is made to module stop mode. Registers cannot be read or written to in module stop
mode. For details, see section 19.5, Module Stop Mode.
MSTPCR is initialized to H'3FFF by a reset and in hardware standby mode. It is not initialized in
software standby mode.
Bit 13—Module Stop (MSTP13): Specifies the TPU module stop mode.
Bit 13
MSTP13
Description
0 TPU module stop mode cleared
1 TPU module stop mode set (Initial value)