7.3.6 Repeat Mode 
In repeat mode, one operation transfers one byte or one word of data. 
From 1 to 256 transfers can be specified. Once the specified number of transfers have ended, the 
initial state of the transfer counter and the address register specified as the repeat area is restored, 
and transfer is repeated. In repeat mode the transfer counter value does not reach H'00, and 
therefore CPU interrupts cannot be requested when DISEL = 0. 
Table 7.7 lists the register information in repeat mode and figure 7.7 shows the memory map in 
repeat mode. 
Table 7.7  Register Information in Repeat Mode 
Name Abbreviation Function 
DTC source address register  SAR  Designates source address 
DTC destination address register  DAR  Designates destination address 
DTC transfer count register AH  CRAH  Holds number of transfers 
DTC transfer count register AL  CRAL  Transfer counter 
DTC transfer count register B  CRB  Not used 
Transfer
SAR or
DAR
DAR o
r
SAR
Repeat area
Figure 7.7 Memory Map in Repeat Mode 