Section 11 16-Bit Timer Pulse Unit (TPU)
Rev. 6.00 Mar. 18, 2010 Page 416 of 982
REJ09B0054-0600
11.4.6 Phase Counting Mode
In phase counting mode, the phase difference between two external clock inputs is detected and
TCNT is incremented/decremented accordingly. In the H8S/2227 Group, this mode can be set for
channels 1 and 2. In other groups, it can be set for channels 1, 2, 4, and 5.
When phase counting mode is set, an external clock is selected as the counter input clock and
TCNT operates as an up/down-counter regardless of the setting of bits TPSC2 to TPSC0 and bits
CKEG1 and CKEG0 in TCR. However, the functions of bits CCLR1 and CCLR0 in TCR, and of
TIOR, TIER, and TGR are valid, and input capture/compare match and interrupt functions can be
used.
This can be used for two-phase encoder pulse input.
When overflow occurs while TCNT is counting up, the TCFV flag in TSR is set; when underflow
occurs while TCNT is counting down, the TCFU flag is set.
The TCFD bit in TSR is the count direction flag. Reading the TCFD flag provides an indication of
whether TCNT is counting up or down.
Table 11.31 shows the correspondence between external clock pins and channels.
Table 11.31 Clock Input Pins in Phase Counting Mode
External Clock Pins
Channels A-Phase B-Phase
When channel 1 or 5
*
is set to phase counting mode TCLKA TCLKB
When channel 2 or 4
*
is set to phase counting mode TCLKC TCLKD
Note: * Not available in the H8S/2227 Group.