Section 18 D/A Converter
Rev. 6.00 Mar. 18, 2010 Page 711 of 982
REJ09B0054-0600
18.5 Usage Notes
18.5.1 Analog Power Supply Current in Power-Down Mode
If this LSI enters a power-down mode such as software standby, watch, subactive, subsleep, and
module stop modes while D/A conversion is enabled, the D/A cannot retain analog outputs within
the given D/A absolute accuracy* although it retains digital values. The analog power supply
current is approximately the same as that during D/A conversion. To reduce analog power supply
current in power-down mode, clear the DAOE0, DAOE1 and DAE bits to 0 to disable D/A outputs
before entering the mode.
Note: * The H8S/2258 Group, H8S/2238B, and H8S/2236B satisfy the specified D/A absolute
accuracy.
18.5.2 Setting for Module Stop Mode
It is possible to enable/disable the D/A converter operation using the module stop control register,
the D/A converter does not operate by the initial value of the register. The register can be accessed
by releasing the module stop mode. For more details, see section 24, Power-Down Modes.