Datasheet

Section 11 16-Bit Timer Pulse Unit (TPU)
Rev. 6.00 Mar. 18, 2010 Page 426 of 982
REJ09B0054-0600
11.8 A/D Converter Activation
The A/D converter can be activated by the TGRA input capture/compare match for a channel.
If the TTGE bit in TIER is set to 1 when the TGFA flag in TSR is set to 1 by the occurrence of a
TGRA input capture/compare match on a particular channel, a request to start A/D conversion is
sent to the A/D converter. If the TPU conversion start trigger has been selected on the A/D
converter side at this time, A/D conversion is started.
In the TPU, a total of six TGRA input capture/compare match interrupts can be used as A/D
converter conversion start sources, one for each channel.
11.9 Operation Timing
11.9.1 Input/Output Timing
TCNT Count Timing: Figure 11.31 shows TCNT count timing in internal clock operation, and
figure 11.32 shows TCNT count timing in external clock operation.
TCNT
TCNT
input clock
Internal clock
φ
N 1 N N + 1 N + 2
Falling edge
Rising edge
Figure 11.31 Count Timing in Internal Clock Operation