Datasheet

Section 27 Electrical Characteristics
Rev. 6.00 Mar. 18, 2010 Page 941 of 982
REJ09B0054-0600
Condition A
Condition B Condition C
Item Symbol Min Max Min Max Min Max Unit
Test
Conditions
Read data
access time 1
t
ACC1
1.0 × t
cyc
65
1.0 × t
cyc
65
1.0 × t
cyc
90
ns
Read data
access time 2
t
ACC2
1.5 × t
cyc
65
1.5 × t
cyc
65
1.5 × t
cyc
90
ns
Read data
access time 3
t
ACC3
2.0 × t
cyc
65
2.0 × t
cyc
65
2.0 × t
cyc
90
ns
Read data
access time 4
t
ACC4
2.5 × t
cyc
65
2.5 × t
cyc
65
2.5 × t
cyc
90
ns
Figures
27.14 to
27.18
Read data
access time 5
t
ACC5
3.0 × t
cyc
65
3.0 × t
cyc
65
3.0 × t
cyc
90
ns
WR delay time 1 t
WRD1
60 50 90 ns
WR delay time 2 t
WRD2
60 50 90 ns
WR pulse
width 1
t
WSW1
1.0 × t
cyc
40
1.0 × t
cyc
30
1.0 × t
cyc
60
ns
WR pulse
width 2
t
WSW2
1.5 × t
cyc
40
1.5 × t
cyc
30
1.5 × t
cyc
60
ns
Write data
delay time
t
WDD
80 70 100 ns
Write data
setup time
t
WDS
0.5 × t
cyc
50
0.5 × t
cyc
37
0.5 × t
cyc
80
ns
Write data
hold time
t
WDH
0.5 × t
cyc
30
0.5 × t
cyc
15
0.5 × t
cyc
60
ns
WAIT setup
time
t
WTS
60 50 90 ns Figure
27.16
WAIT hold time t
WTH
10 10 10 ns
BREQ setup
time
t
BRQS
60 50 90 ns
BACK delay
time
t
BACD
60 50 90 ns
Figure
27.19
Bus-floating
time
t
BZD
100 80 160 ns