Section 16 A/D Converter
REJ09B0140-0900 Rev. 9.00 Page 605 of 846
Sep 16, 2010
H8S/2215 Group
Bit Bit Name Initial Value R/W Description
6 ADIE 0 R/W A/D Interrupt Enable
A/D conversion end interrupt (ADI) request enabled
when 1 is set.
5 ADST 0 R/W A/D Start
Clearing this bit to 0 stops A/D conversion, and the A/D
converter enters the unit state.
Setting this bit to 1 starts A/D conversion. It can be set to
1 by software, the timer conversion start trigger, and the
A/D external trigger (ADTRG). In single mode, this bit is
cleared to 0 automatically when conversion on the
specified channel is complete. In scan mode, conversion
continues sequentially on the specified channels until
this bit is cleared to 0 by software, a reset, a transition to
standby mode, or module stop mode.
4 SCAN 0 R/W Scan Mode
Selects single mode or scan mode as the A/D
conversion operating mode.
0: Single mode
1: Scan mode
3
2
1
0
CH3
CH2
CH1
CH0
0
0
0
0
R/W
R/W
R/W
R/W
Channel Select 3 to 0
Select analog input channels.
When SCAN = 0 When SCAN = 1
0000: AN0 0000: AN0
0001: AN1 0001: AN0 to AN1
0010: AN2 0010: AN0 to AN2
0011: AN3 0011: AN0 to AN3
01××: Setting prohibited 01××: Setting prohibited
10××: Setting prohibited 1×××: Setting prohibited
110×: Setting prohibited
1110: AN14
1111: AN15
Legend:
×: Don’t care
Note: * The write value should always be 0 to clear this flag.