Datasheet

Table Of Contents
Section 13 Serial Communication Interface
REJ09B0140-0900 Rev. 9.00 Page 431 of 846
Sep 16, 2010
H8S/2215 Group
Table 13.11 shows the states of the SSR status flags and receive data handling when a receive
error is detected. If a receive error is detected, the RDRF flag retains its state before receiving
data. Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the
ORER, FER, PER, and RDRF bits to 0 before resuming reception. Figure 13.13 shows a sample
flow chart for serial data reception.
Table 13.11 SSR Status Flags and Receive Data Handling
SSR Status Flag
RDRF
*
ORER FER PER Receive Data Receive Error Type
1 1 0 0 Lost Overrun error
0 0 1 0 Transferred to RDR Framing error
0 0 0 1 Transferred to RDR Parity error
1 1 1 0 Lost Overrun error + framing error
1 1 0 1 Lost Overrun error + parity error
0 0 1 1 Transferred to RDR Framing error + parity error
1 1 1 1 Lost Overrun error + framing error +
parity error
Note: * The RDRF flag retains the state it had before data reception.