Datasheet

Table Of Contents
Section 13 Serial Communication Interface
REJ09B0140-0900 Rev. 9.00 Page 397 of 846
Sep 16, 2010
H8S/2215 Group
Bit Bit Name Initial Value R/W Description
5 ORER 0 R/(W)
*
1
Overrun Error
[Setting condition]
When the next serial reception is completed while
RDRF = 1
The receive data prior to the overrun error is retained
in RDR, and the data received subsequently is lost.
Also, subsequent serial reception cannot be
continued while the ORER flag is set to 1. In clocked
synchronous mode, serial transmission cannot be
continued, either.
[Clearing condition]
When 0 is written to ORER after reading ORER = 1
*
3
The ORER flag is not affected and retains its
previous state when the RE bit in SCR is cleared to
0.
4 FER 0 R/(W)
*
1
Framing Error
[Setting condition]
When the stop bit is 0
In 2-stop-bit mode, only the first stop bit is checked
for a value of 0; the second stop bits not checked. If
a framing error occurs, the receive data is transferred
to RDR but the RDRF flag is not set. Also,
subsequent serial reception cannot be continued
while the FER flag is set to 1. In clocked
synchronous mode, serial transmission cannot be
continued, either.
[Clearing condition]
When 0 is written to FER after reading FER = 1
*
3
The FER flag is not affected and retains its previous
state when the RE bit in SCR is cleared to 0.