Datasheet

Rev. 3.00, 03/04, page 824 of 830
Item Page Revisions (See Manual for Details)
Description amended.
Item Symbol Min. Typ. Max. Unit
Normal
operation
43 55 mA
Sleep
mode
30 40
38 90 µA
Current
consumption
*
5
Standby
mode*
6
I
CC
120
Table 25.2 DC
Characteristics (2)
785
Description amended.
Item Symbol Min. Max. Unit
Write data hold time t
WDH
0.5 × t
cyc
– 5 ns
25.3 AC Characteristics
25.3.3 Bus Timing
Table 25.8 Bus Timing
25.3.4 Multiplex Bus
Timing
Table 25.9 Multiplex Bus
Timing
794,
800
Description amended and added.
Ta = 0°C to +75°C (operating temperature range for
programming/erasing in regular specifications)
Ta = 0°C to +85°C (operating temperature range for
programming/erasing in wide-range specifications)
Item Symbol Min. Typ. Max. Unit
Test
Conditions
Reprogramming
count*
5
N
WEC
100*
3
1000 Times
25.6 Flash Memory
Characteristics
Table 25.16 Flash
Memory Characteristics
813 to
815
Notes: 5. Reprogramming count in each erase block.