Datasheet

Rev. 3.00, 03/04, page 206 of 830
8.6.4 System Control Register 2 (SYSCR2)
SYSCR2 controls the current specifications for the port 6 input pull-up MOSs and address data
multiplex operation.
Bit Bit Name Initial Value R/W Description
7, 6 All 0 R/W Reserved
The initial value should not be changed.
5 P6PUE 0 R/W Port 6 Input Pull-Up Extra
Selects the current specification for the input pull-up
MOS connected by means of KMPCR settings.
0: Standard current specification is selected
1: Current-limit specification is selected
4 0 R/W Reserved
The initial value should not be changed.
3 ADMXE 0 R/W Address data multiplex bus interface enable
0: Normal extended bus interface
1: Address data multiplex extended bus interface
2 to 0 All 0 R/W Reserved
The initial value should not be changed.
8.6.5 Noise Canceler Enable Register (P6NCE)
P6NCE enables or disables the noise canceler circuit at port 6.
Bit Bit Name Initial Value R/W Description
7 P67NCE 0 R/W
6 P66NCE 0 R/W
5 P65NCE 0 R/W
4 P64NCE 0 R/W
3 P63NCE 0 R/W
2 P62NCE 0 R/W
1 P61NCE 0 R/W
0 P60NCE 0 R/W
In 16 bit bus mode in extended mode:
Port 6 operates as the data pin (D7 to D0).
In other mode:
Noise canceler circuit is enabled and the pin state is
fetched in the P6DR in the sampling cycle set by the
P6NCCS.
The operating state changes according to the other