Datasheet
Section 27 Electrical Characteristics
Rev. 3.00 Mar 21, 2006 page 714 of 788
REJ09B0300-0300
Table 27.7 Bus Timing (2) (Advanced Mode)
Conditions: V
CC
= 2.7 V to 3.6 V, V
CC
B = 2.7 V to 5.5 V, V
SS
= 0 V, φ = 2 MHz to maximum
operating frequency, T
a
= –20 to +75°C
Condition
10 MHz
Item Symbol
Min Max
Unit
Test
Conditions
Address delay time t
AD
— 60 ns
Address setup time t
AS
0.5 × t
cyc
– 30 — ns
Address hold time t
AH
0.5 × t
cyc
– 20 — ns
CS delay time (IOS)t
CSD
— 60 ns
AS delay time t
ASD
— 60 ns
RD delay time 1 t
RSD1
— 60 ns
RD delay time 2 t
RSD2
— 60 ns
Read data setup time t
RDS
35 — ns
Read data hold time t
RDH
0 — ns
Read data access time 1 t
ACC1
— 1.0 × t
cyc
– 80 ns
Read data access time 2 t
ACC2
— 1.5 × t
cyc
– 50 ns
Read data access time 3 t
ACC3
— 2.0 × t
cyc
– 80 ns
Read data access time 4 t
ACC4
— 2.5 × t
cyc
– 50 ns
Read data access time 5 t
ACC5
— 3.0 × t
cyc
– 80 ns
HWR, LWR delay time 1 t
WRD1
— 60 ns
HWR, LWR delay time 2 t
WRD2
— 60 ns
HWR, LWR pulse width 1 t
WSW1
1.0 × t
cyc
– 40 — ns
HWR, LWR pulse width 2 t
WSW2
1.5 × t
cyc
– 40 — ns
Write data delay time t
WDD
— 60 ns
Write data setup time t
WDS
0 — ns
Write data hold time t
WDH
20 — ns
WAIT setup time t
WTS
60 — ns
WAIT hold time t
WTH
10 — ns
Figures 27.11
to 27.15