Datasheet

Section 16 I
2
C Bus Interface (IIC) (Optional)
Rev. 3.00 Mar 21, 2006 page 476 of 788
REJ09B0300-0300
Table 16.9 I
2
C Bus Timing (SCL and SDA Outputs)
Item Symbol Output Timing Unit Notes
SCL output cycle time t
SCLO
28t
cyc
to 256t
cyc
ns
SCL output high pulse width t
SCLHO
0.5t
SCLO
ns
SCL output low pulse width t
SCLLO
0.5t
SCLO
ns
SDA output bus free time t
BUFO
0.5t
SCLO
1t
cyc
ns
Start condition output hold time t
STAHO
0.5t
SCLO
1t
cyc
ns
Retransmission start condition output
setup time
t
STASO
1t
SCLO
ns
Stop condition output setup time t
STOSO
0.5t
SCLO
+ 2t
cyc
ns
Data output setup time (master) 1t
SCLLO
3t
cyc
Data output setup time (slave)
t
SDASO
1t
SCLL
(6t
cyc
or 12t
cyc
*)
ns
Data output hold time t
SDAHO
3t
cyc
ns
See figure
28.29.
Note: * 6t
cyc
when IICX is 0, 12t
cyc
when 1.
4. SCL and SDA inputs are sampled in synchronization with the internal clock. The AC timing
therefore depends on the system clock cycle t
cyc
, as shown in section 28, Electrical
Characteristics. Note that the I
2
C bus interface AC timing specifications will not be met with a
system clock frequency of less than 5 MHz.
5. The I
2
C bus interface specification for the SCL rise time t
sr
is 1000 ns or less (300 ns for high-
speed mode). In master mode, the I
2
C bus interface monitors the SCL line and synchronizes
one bit at a time during communication. If t
sr
(the time for SCL to go from low to V
IH
) exceeds
the time determined by the input clock of the I
2
C bus interface, the high period of SCL is
extended. The SCL rise time is determined by the pull-up resistance and load capacitance of
the SCL line. To insure proper operation at the set transfer rate, adjust the pull-up resistance
and load capacitance so that the SCL rise time does not exceed the values given in table 16.10.