Datasheet

Section 13 Timer Connection
Rev. 3.00 Mar 21, 2006 page 342 of 788
REJ09B0300-0300
13.4.8 VSYNCO Output
With the VSYNCO output, the meaning of the signal source to be selected and use or non-use of
modification varies according to the IVI signal source and the waveform required by external
circuitry. The VSYNCO output modes are shown in table 13.11.
Table 13.11 VSYNCO Output Modes
Mode IVI Signal IVO Signal Meaning of IVO Signal
IVI signal (without fall
modification or IHI
synchronization)
VFBACKI input is output directly
IVI signal (without fall
modification, with IHI
synchronization)
Meaningless unless VFBACKI input is
synchronized with HFBACKI input
IVI signal (with fall
modification, without IHI
synchronization)
VFBACKI input fall is modified before output
IVI signal (with fall
modification and IHI
synchronization)
VFBACKI input fall is modified and signal is
synchronized with HFBACKI input before
output
No signal VFBACKI
input
IVG signal Internal synchronization signal is output
IVI signal (without fall
modification or IHI
synchronization)
CSYNCI/HSYNCI input (composite
synchronization signal) vertical
synchronization signal part is separated
before output
IVI signal (without fall
modification, with IHI
synchronization)
CSYNCI/HSYNCI input (composite
synchronization signal) vertical
synchronization signal part is separated, and
signal is synchronized with CSYNCI/HSYNCI
input before output
IVI signal (with fall
modification, without IHI
synchronization)
CSYNCI/HSYNCI input (composite
synchronization signal) vertical
synchronization signal part is separated, and
fall is modified before output
IVI signal (with fall
modification and IHI
synchronization)
CSYNCI/HSYNCI input (composite
synchronization signal) vertical
synchronization signal part is separated, fall is
modified, and signal is synchronized with
CSYNCI/HSYNCI input before output
S-on-G
mode or
composite
mode
PDC signal
IVG signal Internal synchronization signal is output