REJ09B0300-0300
Bit Bit Name Initial Value R/W Description
3
2
1
0
HOINV
VOINV
CLOINV
CBOINV
0
0
0
0
R/W
R/W
R/W
R/W
Output Synchronization Signal Inversion
These bits select inversion of the output phase of the
horizontal synchronization signal (HSYNCO), the
vertical synchronization signal (VSYNCO), the clamp
waveform (CLAMPO), and the blanking waveform
(CBLANK).
HOINV:
0: The IHO signal is used directly as the HSYNCO
output
1: The IHO signal is inverted before use as the
HSYNCO output
VOINV:
0: The IVO signal is used directly as the VSYNCO
output
1: The IVO signal is inverted before use as the
VSYNCO output
CLOINV:
0: The CLO signal (CL1, CL2, CL3, or CL4 signal) is
used directly as the CLAMPO output
1: The CLO signal (CL1, CL2, CL3, or CL4 signal) is
inverted before use as the CLAMPO output
CBOINV:
0: The CBLANK signal is used directly as the CBLANK
output
1: The CBLANK signal is inverted before use as the
CBLANK output