Datasheet

Section 27 Electrical Characteristics
Rev. 3.00 Mar 21, 2006 page 750 of 788
REJ09B0300-0300
Condition A Condition B Condition C
10 MHz 16 MHz 20 MHz
Item Symbol Min Max Min Max Min Max Unit
Test
Conditions
Read data
access time 4
t
ACC4
2.5 ×
t
cyc
50
2.5 ×
t
cyc
35
2.5 ×
t
cyc
25
ns
Read data
access time 5
t
ACC5
3.0 ×
t
cyc
80
3.0 ×
t
cyc
55
3.0 ×
t
cyc
40
ns
HWR, LWR
delay time 1
t
WRD1
60 45 30 ns
HWR, LWR
delay time 2
t
WRD2
60 45 30 ns
HWR, LWR
pulse width 1
t
WSW1
1.0 ×
t
cyc
40
1.0 ×
t
cyc
30
1.0 ×
t
cyc
20
ns
HWR, LWR
pulse width 2
t
WSW2
1.5 ×
t
cyc
40
1.5 ×
t
cyc
30
1.5 ×
t
cyc
20
ns
Write data
delay time
t
WDD
60 45 30 ns
Write data
setup time
t
WDS
0 0 0 ns
Write data
hold time
t
WDH
20 15 10 ns
WAIT setup
time
t
WTS
60 45 30 ns
WAIT hold
time
t
WTH
10 5 5 ns
Figures
27.11 to
27.15